This STREAM SELECTOR UNIT is based on a popular Microcontroller. The system is designed to control the timing of stream selection of up to Four streams system using its timer and relay outputs. It can also generate Sample and Hold type analog outputs for each stream.
No. of Streams: up to 4
Operating Voltage: 110-230 VAC +/- 10%, 1 Phase, 50 Hz Nominal
Key board: 12 keys keypad
Display: 20 Character x 4 Line LCD with back lit
Relays:Stream selection: 4 Relays 1 C/O type
Relay Contact rating: 2A/250 AC, Resistive for each relay
Stream selection logic: time based and/or external input triggered
Digital Inputs: 1 (Potential free)
Analog Inputs: 1 channels, 4 to 20 mA
Analog Output: 4 Channels, 4 to 20 mA, S/H type
Dimension:
- Outer: 192 (W) x 96 (H) x 160 mm (D)
- Cutout: 186 (W) x 92 mm (H)
Enclosure: DIN standard, General purpose, Metallic, Panel Mount