Micro controller based unit
It has 64 KB EEPROM for data & parameter storage
Operating Supply: 110-230VAC
Keyboard: Eight keys membrane like Keypad
Display: 4 digit LED (for each channel)
Input: Load cell Sensor (Up to Four channel)
Excitation Voltage: 10VDC
Number of components: Up to 4
Discharge sequence Programmable
Onboard RTC
Field Programmable parameters:
- Set points for four components
- Offset for four components
- Minimum weight to start new batch
- Gate Time: delay time between feeding of the four components
- Dead Weight: Minimum to start a new batch
- Control Outputs: Total 4 relay outputs:
Four relays to control Feeding of components
Digital Inputs: 2 digital inputs (One for water metering & one for remote command)
Calibration: Offset & Span calibration through software using keypad
Serial Interface:
- RS-232/RS-485 (for Printer/Computer/HMI/Pen drive module)
Mechanical Data: Mounting: Panel mounting
- Cutout size: 138 mm x 138 mm
- Outerdimension:144mm(W)x144mm(H)x125mm (Depth)
Enclosure: Metallic, Powder coated, General Purpose